Hướng dẫn Update Firmware/flash deadphone bằng Phoenix 2011 (update 27/5/2011)

Thảo luận trong 'S60 3rd: FIRMWARE - SIGN - HACKPHONE & HACK APP' bắt đầu bởi caoquy8x, 13 Tháng tư 2010.

  1. caoquy8x Thành viên

    Hướng dẫn Update Firmware Offline bằng Phoenix
    (Khuyên Dùng Vì Độ An Toàn Cao Đến 99,99%)


    Phoenix Service Software 2011.14.004.45945 Cr@cked & Original (Update 27.05.2011)

    [​IMG][​IMG][​IMG]

    Mã:
    CHANGE HISTORY Version 1: 09.05.2011 Initial version for v 2011.14.3.45843 Vesrion 2: 24.5.2011. RM 701 support added, package version number updated to 2011.14.4.45945. Otherwise same as earlier 2011.14.3.45843
    
    INTRODUCTION Main component versions in the release: * DK2 Driver Version 07.14.0.25 * Nokia Connectivity Cable USB Driver Version 7.1.40.0 * Flash Update Package 2011.16.000 * FLS-x Drivers Version 2.09.28 * FUSE Connection Manager v 2011.13
    
    MAIN CHANGES & ERROR CORRECTIONS FROM PREVIOUS VERSION 2011.8.5.45529
    
    New Products added
    * RM-776, RM-775, RM-763, RM-773, RM-670, RM-765, RM-774
    
    New features
    * New version of FUSE connection Manager
    * New version of Flash Update Package
    * New version of Autotuning components
    * New version of Product API
    * New version of Connectivity Cable Driver
    * Torque Information - menu implemented. Information concerning screw tightening torques can be shown if product specific data package contains pictures / information files
    * Simple Multi Software Updater UI added
    
    Error Corrections & changes
    * Improvements to Smart Card Activator: User is now asked to wait during the delay when smart card data is being read
    * Crash file upload server correction
    * Tucson support for RM-733, RM-732 and 713 implemented. Please note that for these products only Tucson functions can be done with Phoenix, Care Suite must be used for all other activities.
    
    Please note:
    * New common data package location in use. Please see document SR1315 in KICS Information Center for further information.
    * All Nokia Service Software Applications will use following location for product specific data: - Windows XP: C:\Documents and Settings\All Users\Application Data\Nokia\Packages - Windows 7: C:\Program Data\Nokia\Packages
    * During installation, Data Packages should be installed in these directories, if they install to any other location by default. target folder for local data packages can be changed in the installation wizard manually
    * This version contains the latest Tucson components. Therefore it is not necessary to use Tucson Add-On Installation Packages
    * Before you start Phoenix or Care Suite installation to Windows 7 the User Account Control (UAC) should be turned off from Windows Control Panel settings.
    * For more information concerning new options in "Firmware Update" - menu and their use, Please see documents SR1313 and SR1659 in KICS Information Center.
    * Tucson operations combined with "flash" - option are now handled in the same way as "refurbishment", which requires Mass Memory Content File to be available.
    * Do not use Flash option simultaneously with product code change for USB Only phones, flash phone separately with Firmware Update
    * It is recommended to use FPS-21 flash prommer with TCPIP connection when refurbishing USB Only - phones (RM-596 etc) due to mandatory optional MMC file size.
    * Connection media to FLS-5 must be configured to be "USB_FBUS", after FLS-4 support has been removed FBUS does not work anymore with FLS-5
    
    KNOWN ERRORS & LIMITATIONS
    * Software downgrade with Tucson system is only possible for BB 5.0 products supporting the Data Package 2 concept.
    * Flashing with setup FLS-5, SS-46 and product specific adapter is not supported anymore. FLS-5 can be used with other product specific cables and adapters, but not with SS-46 Interface Adapter.
    * If you install old DCT-4 data packages, Flash Update Package File installation path may be wrong. This is caused by very old DCT-4 data packages which contain Flash Update Package and overwrite current information during installation. If you experience problems when updating FPS-x prommers, please check that Phoenix “Prommer maintenance” is looking for the files from the correct location which is “C:\Program Files\Common Files\Nokia\Tss\Flash”. If not, Phoenix will show error “Update via ini – file failed”. In this case, select “Update” from that Phoenix “Prommer maintenance” – UI, browse to correct directory and select “fpsxupd.ini” for all other prommers except the FPS-8.
    * Refurbishment flashing and product code change for RX-51 product requires SX-4 card to be available.
    * FPS-21 flashing for RX-51 works only with TCPIP connection. FPS-21 prommer with new HW version 11 has been released to correct this. Sales pack code is 0089J83 , old HW version is not delivered anymore
    * Please refer to product specific documents and instructions concerning the limitations of the RX-51 product
    * RX-51 flashing does not work when CU-4 is used
    * RX-51 Product Code changes work only without FLASH option, please flash phone separately
    * When version 2010_12_8_42304 or newer with FUSE connection manager is installed on top of older Phoenix versions, there may be an additional delay of several minutes when you start Phoenix for the first time. Please wait patiently; Phoenix will start after configuration is finished.
    * When using Data Package download functions with online connection, download times may occasionally be long. This is not caused by Phoenix (or Care Suite). The download speed from online servers is occasionally is known to be slow, depending on how data is buffered on caching servers.
    * After you close Phoenix, it may not restart. To rectify this: - Use Windows Task Manager to manually shut down phoenix.exe and FuseService.exe processes, or optionally restart your PC
    * It is not possible to program Mass Media Content file to some devices over direct USB cable connection, due to the large size of the file. For these models a feature called “Media Check” has been implemented. When this type of product is connected to service software / PC via direct USB cable the refurbishment option will be disabled. Please use a flash prommer.
    * To be able to use the help files in Windows 7 you need to install Windows Help program (WinHlp32.exe) for Windows 7. Ways to locate WinHlp32.exe: - Start Phoenix with online connection to Internet, select "Help" and "Phoenix help". Click the "Microsoft Help and Support" website link. Download WinHlp32 and install it.- Go to http://www.microsoft.com. Type "WinHlp32" to "Search Microsoft.com" - field. Locate Windows Help program (WinHlp32.exe) for Windows 7 and install it
    * When using flash prommers, only one connection type to one prommer is allowed. Please use either NFPD USB or NFPD TCPIP connection to one prommer, not both connections to same prommer
    
    INSTALLATION
    * If you have Phoenix External 2007.4.6.170 or older you must uninstall it before installing this release.
    * Download Phoenix_Service_Software_2011_14_3_45843.exe application file to your computer (e.g. C:\TEMP).
    * Close all other programs.
    * Disconnect all flash prommers and phones which may be connected to PC via USB connection (reconnect them only after Phoenix installation has been completed)
    * Run Phoenix_Service_Software_2011_14_3_45843.exe and follow instructions on the screen to install Phoenix Service Software
    * Connect a dongle (PK-1, PKD-1, FLS-4S, FLS-5) when message appears on the screen
    * If you are prompted to update any existing driver or file versions, select “yes”.
    * Depending on the operating system, the PC may require rebooting.
    * Allow Windows to register the Phoenix components.
    * Open Phoenix, use FUSE Connection Manager to configure connections depending on the tools you use
    * If you use CU-4, please pair the connection with service adapter by selecting “pair with service adapter” - option
    * Update your prommer with the latest software included in this installation package.
    * Install and use the latest available product specific data packages or flash bundles
    Supported operating systems and user rights
    
    * Windows XP Service Pack 1 or higher
    * When installing Phoenix into Win XP you must have local admin rights.
    * When using in Win XP, user must have power user rights.
    * Windows 7 32 Bit version
    A. Hướng dẫn update firmware bằng Pheonix

    1. Đầu tiên các bạn cần phải tải FW điện thoại của mình về PC bằng navifirm ở file đính kèm


    - Copy thư mục RM-346 (đối với E71 RM-346) vào C:\Program Files\Common Files\Nokia\DataPackage\Products\ (Nếu không có thì các bạn tạo có thể tự tạo ra) Hoặc C:\Program Files\Nokia\Phoenix\Products\ Hoặc C:\Program Files (x86)\Nokia\Phoenix\Products\ (Đối với windows 64bit)


    - Copy thư mục RM-346 (đối với E71 RM-346) vào C:\Program Files\Common Files\Nokia\DataPackage\Products (Nếu không có thì các bạn tạo có thể tự tạo ra)



    - Phân biệt các bản FirmWare dành cho các khu vực.
    - Thông thường các máy Nokia chính hãng được phân phối tại Việt Nam thì các bạn load FW: APAC - Asia PacificSEAP - Sout East Asia Pacific



    2. Download Pheonix 2011 ở dưới về, cài trên PC

    3. Cắm điện thoại vào PC thông qua cáp và chọn kết nối PC Suite/Ovi suite

    4. Chạy Phoenix đã được cài sẵn trên PC

    5. Chọn File / Scan Product

    6. Sau khi Scan Product xong Phoenix sẽ nhận ra thiết bị được gắn vào thông qua cáp.

    7. Chọn Flashing / Firmware Update

    8. Thông thường sau khi chọn Firmware Update thì Phoenix sẽ tự nhận ra FW đúng với thông số của điện thoại.

    Chọn Refurbish để Update Firmware.

    - Nếu Phoenix không tự nhận ra FW của máy thì click và biểu tượng hình tròn sẽ hiện ra bảng FW tương ứng với Product Code của từng loại máy. Ở đây bạn có thể chọn thủ công hoặc click vào "Detect Product Automatically" để Phoenix tự động gán FW theo đúng thông số điện thoại.
    - Chọn Ok và chọn Refurbish để Update Firmware.

    9. Sau khi chọn Refurbish để Update Firmware thì các bạn chỉ cần đợi từ 3 - 7 phút là xong.




    B. Hướng dẫn dùng Pheonix ở chế độ deadphone

    Cái này dùng để cứu máy bị mất nguồn (bật không lên,bật chỉ dừng màn hình Nokia,bật chỉ rung….tất tần tật do đang up fw mất điện,do máy lỗi….)

    Nguồn: Hoàng Hải - symbianvn

    Bài này sẽ lấy ví dụ flash deadphone trên Nokia E52 fw 34.001,RM-469 (bật chỉ rung lên màn hình tối thui )

    1. Chép gói firmware theo đường dẫn của Phoenix C:\Program Files\Nokia\Phoenix\Products\RM-xxx (xxx là tên RM của máy,bấm *#0000# để kiểm tra)

    2. Bật phần mềm Phoenix ,chọn File -> Manage Connections

    [​IMG]


    Ở đây chuyển về chế độ No Connection ->Apply ->Close

    [​IMG]


    Ở góc dưới bên phải Phoenix sẽ hiện biểu tượng No Connection như hình dưới

    [​IMG]

    3. Tiếp tục chọn File ->Open Products.Lựa chọn đúng RM máy đang dùng và Ok

    [​IMG]
    [​IMG]


    4. Sau khi phần mềm đã chọn nhận RM-469,tiếp tục chọn Flashing -> Firmware Update. Bấm vào ô tìm như hình

    [​IMG]

    [​IMG]

    Phoenix sẽ hiện ra bảng gồm các gói firmware hiện có trong máy,chọn 1 bản cho tương thích rồi Ok

    [​IMG]

    5. Đánh dấu vào ô Deadphone USB và bấm Refurbish

    [​IMG]

    6. Chờ phoenix chạy đến như hình dưới đây,cắm cáp,bấm nút nguồn phone 1 cái.Phoenix sẽ bắt đầu chạy và nạp bộ firmware vào máy,ngồi chờ mấy phút là xong.

    [​IMG][​IMG]
    [​IMG]




    Download Pheonix 2011

    [​IMG]




    Mã:
    [URL="http://azsharing.com/khoqy4339wvu/Phoenix-Service-Software-2011.14.004.45945-_ed.rar.html"]http://azsharing.com/khoqy4339wvu/Phoenix-Service-Software-2011.14.004.45945-_ed.rar.html[/URL]

    Các file đính kèm:

  2. chauquangtrung

    chauquangtrung Thành viên

    Bài viết:
    15
    Được Like:
    0
    dowload quá chậm

    bạn ơi sao mà tốc độ dowload chậm thế nhị? mình dow gan 5h mà vẫn chưa xong kia
    ma
  3. quangthinh99

    quangthinh99 Thành viên

    Bài viết:
    1
    Được Like:
    0
  4. buiducchi

    buiducchi Thành viên

    Bài viết:
    1
    Được Like:
    0
    bạn ơi chỉ mình cách cài lại firmware bản cũ hơn đi
    mình không up được
  5. Be Yeu

    Be Yeu Super Moderator Staff Member

    Bài viết:
    4,781
    Được Like:
    5,681
    Phoenix không downgrade được nhé bạn . Muốn downgrade bạn phải dùng JAF ( tỉ lệ Deadphone cao ) , muốn chắc chắn thì bạn nên dùng Box chuyên dụng - có ở các cửa hàng sửa chữa uy tín nhé ! )
  6. tra_ung

    tra_ung Thành viên

    Bài viết:
    15
    Được Like:
    0
  7. zennez

    zennez Thành viên

    Bài viết:
    500
    Được Like:
    318
    sau khi mình up fw mới nhất của e72 là 31.023 bằng NSU, bị mất font tiếng việt, làm sao để lấy lại tiếng việt, mong các cao thủ chỉ giáo dùm
  8. Be Yeu

    Be Yeu Super Moderator Staff Member

    Bài viết:
    4,781
    Được Like:
    5,681
    Tìm FW 31.023 APAC rồi chạy lại FirmWare này bằng Phoenix hoặc JAF sẽ có mục đổi code ngôn ngữ khi flashphone ! Thân !
    nguyenngocgiang thích bài này.
  9. mabu

    mabu Thành viên

    Bài viết:
    236
    Được Like:
    125
    Chính xác là có FW VIETNAM hẳn hoi chứ ko phải APAC (dùng Navifirm load RM-530), có lẽ dòng E72 mới ra được người Việt Nam ưa chuộng nên nó có rieng FW chăng!!? :D
  10. mabu

    mabu Thành viên

    Bài viết:
    236
    Được Like:
    125
    Phoenix_Service_Software_2010.08.004.41526_.....ed _Caoquy8x

    Làm theo cách trên của đ/c Caoquy8x không làm sao mà hiện ra được cái Product code, đã dùng Detect Auto cũng chả thấy gì, mặc dù đã laod FW chuẩn (của mình là E72 RM-530), làm theo đúng hướng dẫn, cho vào đúng Folder cần thiết!!! :(

    Liệu có phải do cái Phoenix này ***** chưa chuẩn!?!

    Rất mong các bro chỉ giáo!

    --------------------------fixed---------------

    Bác nì chơi khó ae, làm tui mất cả buổi chiều lọ mọ tìm nguyên nhân, sang cả bên tinh tế xem cái thớt của bác, đến khổ, rốt cục bác hướng dẫn cho vào đường dẫn Program Files\Common Files\Nokia\Data_..., nhưng đúng phải là PF\Nokia\Phoenix.... :(

    Bro nào bị giống tui thì liệu mà xử lý nhá!!! :D

    [​IMG]
    [​IMG]

    THKS.